NEWS CENTER
INDUSTRY NEWS
Use and maintenance:
1. It is recommended that the user unit appoint a special person to be responsible for use and maintenance
2. Regular maintenance 1-2 times a year is the best method for reliable operation and longevity of solenoid valves. The following four conditions inside the solenoid valve are the reasons that hinder the normal operation of the solenoid valve and shorten the life.
⑴, the medium changes during use
⑵, rust inside the takeover
⑶. The oil of the air compressor is oxidized to produce impurities such as carbon particles and tar, which are mixed into the pipeline 2.4 There are impurities such as dust particles and dirt in the pipeline
3. After the solenoid valve is installed or put into operation again after a long period of time out of service, the medium must be passed in for a few tries before it works normally before it can be used officially
4. When the steam valve is put into operation again after being out of service for a long time, the condensed water should be drained and tested several times before it can be put into operation after it works normally.
5.Before maintenance, the power must be cut off and the medium pressure must be removed.
6. The coil assembly should not be disassembled
7. When disassembling the solenoid valve for cleaning, you can use kerosene, trichloroethylene and other solutions. But it should be noted that the rubber parts may swell, so it must be replaced.
8. When disassembling and cleaning, all parts must be restored to their original state in order.
9. Our company has vulnerable parts, please specify when ordering according to the instructions when necessary.
10. If the disassembly sequence, wearing parts and other matters are unclear, please consult the technical department of the headquarters (enquiry hotline: 0577-61711948-8006)
■Installation instructions:
1. Before installation, you should read the product manual carefully, check whether the product fully meets the requirements for use, be familiar with the main points of installation, and make preparations.
2. When installing, the solenoid valve coil should be upward and keep the vertical position. The arrow or mark on the solenoid valve should be consistent with the flow direction of the pipeline. It should not be installed in a place with splashing or water leakage.
3. Fully flush the pipeline with a pressure of 0.3 MPa before taking over the pipe to completely remove the metal powder sealing material residue and rust in the pipeline; the working medium of the solenoid valve should be clean and free of particulate impurities. It is recommended to install a filter before the valve and install the steam pipeline Drain valve; the dirt and filter on the surface of solenoid valve inner parts must be cleaned regularly.
4. When the solenoid valve fails, in order to isolate the solenoid valve in time and ensure the normal operation of the system, it is best to install a bypass device.
5. Do not install the valve in a recessed part of the pipeline to prevent steam, condensate, impurities, etc. from depositing in the valve and hindering the operation.
6. Ordinary solenoid valves cannot be used in flammable and explosive hazardous situations.
7. In the case of insufficient pipe rigidity, it is recommended to fix the pipes before and after the valve with brackets to prevent vibration when the solenoid valve is working.
8. Pressure gauges should be installed on the pipes before and after the solenoid valve to observe the pipe pressure.
■Main dimensions:
malfunction
Cause Analysis
Approach
No action when energized
Poor power connection
Power supply voltage fluctuation is not within the allowable range
The coil is short-circuited or burned out
Connect the power cord
Adjust the voltage within the normal range
Replace the coil
Fluid cannot pass when the valve is opened
Fluid pressure or working pressure difference does not meet
Fluid viscosity or temperature does not match
Dirt and impurities are mixed around the valve core and the moving iron core
The filter or pilot valve hole before the valve is blocked
The working frequency is too high or the service life expires
Adjust pressure or working pressure difference or replace suitable products
Replace suitable products
To clean the interior, a filter valve must be installed before the valve
Clean the filter or pilot valve hole in time
Change product model or replace with new product
The fluid cannot be cut off when closing the valve
Fluid viscosity does not meet
Fluid temperature does not meet
Spring deformation or expiration of life
Defective valve seat or adhesion of dirt
The gasket comes out `defective or deformed
Clogged balance orifice
The working frequency is too high or the service life expires
Replace suitable products
Replace suitable products
Add gasket or replace spring
Clean, grind or renew
Update, reassemble
Clean in time
Then change the product model or change to a new product
Leakage
Loose pipe connection
Damaged outer seal of pipe connection
Tighten the bolt or takeover thread
Replace the seal
Serious internal leakage
Fluid temperature does not meet
There are impurities or defects in the pilot valve seat and the main valve seat
The pilot valve and the main valve seal come out or deformed
Poor assembly, deformation or expiration of life of the spring
Working frequency is too high when in use
Adjust fluid temperature or replace
If so, clean or grind to repair or replace
Replace the gasket
Replace the spring
Change product model or replace with new product
Excessive noise when energized
Loose fasteners
Voltage fluctuation, not within the allowable range
Fluid pressure or working pressure difference is not suitable
Fluid viscosity does not meet
Impurities on the suction surface of the armature
Tighten
Adjust to within the normal range
Adjust pressure or working pressure difference or replace product
Replace suitable products
Clean in time
Thank you for your interest in our corporate culture. Please continue to understand our products: induction sanitary ware, washing machines, solar energy, water heaters, washing equipment, food, garden irrigation, IC card water meters, and solenoid valves for engineering water control systems, solenoid valves, pulse solenoid valves , Bistable pulse solenoid valve, flow valve, small punch solenoid valve, large punch solenoid valve, faucet solenoid valve, induction sanitary ware solenoid valve, integrated faucet solenoid valve, adjustable temperature solenoid valve, solar solenoid valve, washing machine solenoid valve, Garden irrigation solenoid valve.
-